Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

UTL Air Conditioning Technology Co., Ltd.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Zoe Zheng
  • 电话:86-20-62327131
  • 传真:86-20-66612343
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > 36000 BTU Ductless Floor Ceiling Air Conditioner and Heat Pump
36000 BTU Ductless Floor Ceiling Air Conditioner and Heat Pump
单价 $808.00 / Sets对比
询价 暂无
浏览 66
发货 Chinaguangdongguangzhou
库存 50000Sets
过期 长期有效
更新 2020-04-23 03:52
 
详细信息
Product Name: 36000 BTU Ductless Floor Ceiling Air Conditioner and Heat Pump Model NO.: UCHA-36FDC Condition: New Power Type: DC Power Source: Electrical Cooling/Heating: Cooling/Heating China Energy Efficiency Standard: Level 2 Certification: CE, UL Indoor Machine Noise: 36-49dB Usage: Room Capacity: 27000-48000 BTU Type: Inverter Air Conditioner Eer: 10.71 Cop: 3.05 Seer: 17.19 Air Volume: 676 Cfm Trademark: VKIN/UTL Transport Package: Carton Specification: 37.1*26.2*9.5 in Origin: China HS Code: 8415812001 Product Description These R410A DC INVERTER SPLIT FLOOR-CEILING AIR-ConDITIONER are universal mounted, meaning they can mount low on the floor or low on the wall, yet high enoughfor a vacuum to get under them. They can also be mounted on the ceiling. A popular application for this model is in hallways where wall space is limited.An intelligent approach to comfort with a single unit that is equally at home standing upright as a floor unit or fitted horizontally to the ceiling without modification. Extremely quiet and energy efficient, they are ideal for residential or commercial situations.Through new, advanced technology, Inverter air conditioners are more economical to operate and quieter to run than conventional units. They can handle greater extremes in temperature, are smoother and more stable in operation, and reach the desired temperature more quickly than conventional air conditioners.ModelUCHA-12FDCUCHA-18FDCUCHA-24FDCUCHA-36FDCUCHA-48FDCUCHA-60FDCPower supplyPh-V-Hz1, 230V, 60Hz1, 230V, 60Hz1, 230V, 60Hz1, 230V, 60Hz1, 230V, 60HzCoolingCapacityBTU119400(3400-13300)17000(7840-19700)23200(12690-29000)10400(5000-12000)13800(6000-14200)17000(6500-18500)InputW960(270-1580)1440(750-2200)2131(1300-3450)3313(2100-4350)4647(2500-4950)5762(2600-6500)Rated currentA4.36(1.5~6.85)6.55(3.4~10.0)9.2(6.0~16.0)14.7(9.5-18.9)20.2(11.6-22.5)25.05(12.1-28.9)EERBTU/W12.4111.8310.8810.7110.1310.06HeatingCapacityBTU12960(3680-15350)18420(8180-21500)24500(13640-31000)10700(6000-12000)14300(6300-14400)17600(8100-19100)InputW1172(260-1680)1700(675-2280)2320(1310-3600)3507(2400-4600)4912(2050-5600)6170(2780-6800)Rated currentA5.1(1.5-7.32)7.4(3.5-11.2)9.7(6.1-16.3)15.5(10.4-20.5)21.3(8.9-24.8)26.82(12.9-29.5)COPW/W3.243.183.13.052.912.85SEERBTU·h/W·h18.5617.9117.8117.1916.6816.31Indoor air flowCFM411500576676811970Indoor unitDimension (W*H*D)Inch37.1×26.2×9.537.1×26.2×9.552×26.2×9.552×26.2×9.566.9×26.2×9.566.9×26.2×9.5Packing (W*H*D)Inch38.8×29.6×12.338.8×29.6×12.353.6×29.8×12.153.6×29.8×12.169×30×12.369×30×12.3Net/Gross weightIbs85.5/92.597.8/101.5106.8/120.8113.6/117.9126.0/131.0139.5/146.5Outdoor unitDimension (W*H*D)Inch31.2X21.5X9.833X23.7X11.132.3X27.7X12.134.3X31.2X1449.1X32.4X12.149.5X36.3X15.2Packing (W*H*D)Inch34.7X25.5X1438.2X25X15.637.8X29.1X1640x32.8X17.749.5X37.8X1650x41.7X19.1Net/Gross weightIbs94.5/101.2117.0/121.5148.5/152.8144.3/149.5229.5/249.7239.5/258.5Noise levelIndoordB(A)30-4232-4733-4835-4936-5036-52OutdoordB(A)485355575959Dehumidification CapacityL/H1.081.882.42.953.654.5MAX.Pipe LengthFt32.8132.8149.2149.2165.6282.02MAX.Height DifferenceFt26.2526.2532.8132.8149.2149.21Pipe Size Liquid/GasInch1/4 - 1/21/4 - 1/23/4 - 5/83/4 - 5/81/2 - 3/41/2 - 3/4RefrigerantR410aR410aR410aR410aR410aR410aDesign pressurePsi600600600600600600Operation tempºF62 - 8862 - 8862 - 8862 - 8862 - 8862 - 88Ambient tempºF-13- 116-13- 116-13-116-13- 116-13- 116-13- 116Application areaFt2151-237210-324486-648810-9721080-11881188-1350Rated cooling test conditions:Outdoor dry bulb temperature/Wet bulb temperature95.0ºF75.0ºF Indoor dry bulb temperature/Wet bulb temperature80.0ºF67.0ºFRated heating test conditions:Outdoor dry bulb temperature/Wet bulb temperature47.0ºF43.0ºF Indoor dry bulb temperature/Wet bulb temperature70.0ºF60.0ºFThe difference between the fixed-frequency and frequency of::Fixed-frequency machine: the outdoor unit operating ambient temperature range is relatively narrow (19-109ºF) and can not adjust the size of the cooling / heating capacity of the indoor temperature changes, the machine open between stops, the indoor temperature fluctuations, feels suddenly cold suddenly hot.Frequency Machine: the outdoor unit operating ambient temperature range is wide (-13-126ºF) and can change depending on the temperature and adjust the size of the room cooling / heating capacity, the indoor temperature a smooth transition, the temperature fluctuation is small, automatic climate control, power consumption energy-saving effect is remarkable.Welcome to VKINVKIN is one of the largest manufacturers of DC inverter Air conditiner,DC inverter Swimming Pool Heat Pumps,DC inverter Heat Pump Water Heaters in China. VKIN's vision is "to be a young company forever, with the human wisdom to achieve the harmonious development of man and nature, TRUST ALWAYS."VKIN has more than 100 national patents covering air conditioning, heat pump and heat pump technology, building a complete heat pump industry chain. In addition, VKIN has developed hardware and software for intelligent device control that allows customers to customize VKIN devices to their individual needs. VKIN provides comprehensive energy-saving overall solutions and products for medium and high-end users both at home and abroad, including air conditioners, constant temperature and humidity machines, swimming pool heat pumps, room heating and heat pumps, industrial heat pumps and the like.As an international company, VKIN attaches great importance to the high-end overseas markets. More than 90% of its products are exported to North America, Europe, North America, the Middle East, Australia and other developed regions.